- Spray Booths[7]
- Wheel Alignment[10]
- Gas Analyzers[6]
- Body Repair Equipment[10]
- Car Lifts[7]
- Other Vehicle Equipment[10]
- Welding Torches[2]
- Air-Compressors[7]
- Tire Changers[4]
- Gasoline Generators[7]
- Diagnostic Tools[2]
- Testing Equipment[8]
- Lathe[7]
- Scanners[6]
- Car Washer[4]
- Steam Cleaners[2]
- Drying Equipment[1]
- Cooling System[4]
- Cleaning Equipment[3]
- Pneumatic Tools[2]
- Tool Cabinet[1]
- Hydraulic Tools[2]
- Car Jacks[3]
- Jacks[1]
- Wrench[1]
- Electric Drill[1]
- Tool Parts[5]
- Other Car Care Equipment[3]
- Contact Person : Mr. Chen Biao
- Company Name : Guangzhou Baohua Auto Maintenance Equipment Trade Co., Ltd.
- Tel : 86-20-22019669
- Fax : 86-20-36474865
- Address : Guangdong,Guangzhou,NO.208,Guangyuan Middle Road,Baiyun District,Guangzhou,china
- Country/Region : China
auto emission analyzer NHA-500
NHA-500 Automotive Emission Analyzer (5-gas/portable )Main Features and Specifications
Measure concentration of HC, CO, CO2,O2 and NO English menu for easy operations.LCD screen.3.Automatic zero reset.
4.Assembled with advances NDIR components and gas sensors.
5.Automatic calculation and display of Air-Fuel Ratio.
6.Small vacuum ,light weight and easy to carry
7.Equipped with RS-232C digital serial communication interface.
8.Equipped with rotation speed and oil temperature measure ports.
9.With functions of License Plate Number entry and time display.
10.800 group of data storage and review.
11.In compliance with accuracy requirement of ISO 3930 or OIML r99 Class 0.
Main Technical Specification
1.Measure Range
HC: 0~10,000 × 10-6ppm vol
CO: 0~10 ×10-2% vol
CO2:0~18 ×10-2%
O2 : 0~23 ×10-2 %
NO: 0~5,000 × 10-6 (ppm) vol
2.Measurement Accuracy:
HC: 0~ 2,000 mmp vol:
±12 mmp vol (abs) or ± 5% (rel.)
2,001 ~ 9,999 mmp vol: ±10%(rel.)
CO: ± 0.06 % vol (abs.) or ± 5% (rel.)
CO2: ±0.5 % vol (abs.) or ± 5% (rel.)
O2: ±0.1 % vol (abs.) or ± 5% (rel.)
NO:: ±25 mmp vol (abs) or ± 4% (rel.)
3.Resolution:
HC: 1 ppm vol
CO:0.01 % vol
CO2 :0.01 % vol
O2 :0.01 % vol
No: 1 ppm vol
Response Time :Less than 10s for T90 ( O2,less than 12s .NO, less than 15s)
4.Warm-up Time:8min.
(A)(ambient temperature is not lower than 20°C)
(B)Fast measurement can be started at 10min.
5.Power Supply : AC220V ±10% 50Hz ± 1Hz or DC12V (optional DC-AD inverter)
6.Net Weight :9kg
7.Outer Dimension:260mm(W) *180mm(H)*450mm(D)
auto emission analyzer NHA-500